Permanent surge single-phase protector + IGA...
Permanent surge single-phase protector + IGA 2x16A 10kA COMBI-2P16 - Toscano

Permanent surge single-phase protector + IGA 2x16A 10kA COMBI-2P16 - Toscano

€50.69 Tax included

€41.89 tax excl.

Module for permanent surge protection with built-in IGA 2x16A for single-phase installations.

Surge protection module provides protection against permanent surges due to increases in mains voltage, incorporates a 2x16A IGA with a breaking capacity of 10kA.

Reference: COMBI-2P16

Diagrama descargador sobretension transitoaria monofásico V2T-60 (1)

Toscano_version 1 color sin leyenda
Representative image for illustrative purposes, the item supplied will correspond to the specifications indicated.

No queries yet, leave the first!
 

Permanent surge protection assembly, associated with a 2-pole cutting device (IGA) with a breaking capacity of 10kA according to IEC-EN 63052, curve "C".

The operation of this protection module is to cause the disconnection of the electrical system single-phase when it is subjected to a higher voltage than it had to receive, in a continuous way. When any of the firing coils is subjected to a voltage greater than 265 Vac, it produces the opening of the IGA contacts, leaving all the circuits fed downstream of the VIGIVOLT COMBI protector without voltage.

This device, very compact and simple installation, provides a very high protection against permanent surges, incorporates an IGA (mcb circuit breaker) with a breaking capacity of 10kA. It has a visual cut-off status indicator.
Suitable for use in domestic installations, electric vehicle charging points and industry.

The supply includes:

  • 2-Pole IGA (single-phase): 2x16A
  • Permanent surge protector (firing coil)

The whole assembly is supplied fully assembled and wired.

Specifications:

  • Manufacturer/Supplier: Toscano
  • Reference: COMBI-2P16
  • Mcb Rated Current: 16A
  • Number of protected poles: 2 (2x16A)
  • Mcb Breaking Capacity: 10kA
  • Trigger voltage: >265Vac ±2%
  • Surge response time: According to UNE-EN 50550 standard
  • mcb circuit breaker shooting curve : "C"
  • Maximum cable section in terminals: 25 mm2
  • Nº of modules occupied on din-rail: 3
  • Regulations: EN 60898 / EN 50550
  • Marking: CE

conexionado combi-2p toscano adajusa

For the correct functioning of the equipment, the phase must be connected to the terminal block "L" and the neutral in the terminal block "N"

To expand the information you can download the technical sheet by clicking on the "Attachments" tab.
Material for professional use, install in compliance with the regulations in force at the place of installation.